中文
Vibration test system

VENZO 640 Shock Test System

VENZO 640 shock test systemis the tailored instrument for drop tester, shock tester and bump testing machine. It allows the test engineer to acquire any transient event such as drop test, crash test or shock pulses.When the external input match the defined trigger conditions- trigger level, slope and position, VENZO 640 will trigger to capture the transient event and display the pulse graphics, and additional SRS analysis gives the instant estimation of the potential damage. A series of pulses can be captured and in the mean while throughput to disc in a continuous data stream for post-analysis.VENZO 640 can also control the shock machines’ movements as specific requirements of customers.

Features

  • 100Mbps Ethernet port connection
  • Capture Duration: 1ms-10,000ms
  • Pulse Duration: 0.05ms to 5,000ms
  • Maximum sampling rate up to 204.8 kHz
  • Acceleration range up to 100,000gn
  • Standard:  MIL-STD-810, MIL-STD-202-213, IEC 68-2-27 or user defined
  • Analysis Function: FFT, SRS Analysis, Force Deflection Analysis, Rotational Shock Analysis, Shock Response Analysis
  • Independent low-pass or high-pass filter for each channel
  • Auto generation of test report in Word or PDF format

Hardware

Input 4 channels
Input Interface BNC Connector
Input Resolution 24-bit ADC
Coupling AC Gnd, AC Dif, DC Gnd, DC Dif, Charge, IEPE
TEDS IEEE 1451.4 compliant, automatic-reading
Anti-aliasing Filter analog and digital anti-aliasing low-pass filters
Input Dynamic Range 135dB
SNR <-100dB
Input Voltage Ranges ±10, ±1 or ±0.1 VPEAK
Input Impedance 1MΩ(single-ended)2MΩ(differential)
Input Protection Voltage ± 36VPEAK without damage
Input Channel Crosstalk <-100dB@1kHz
Amplitude Channel Match 0.1 dB
Channel Phase Match better than ±1.0 degree, up to 20 kHz
Input Signal Type Charge, Voltage, High-integrated
Total Harmonic Distortion <-100dB @ 1kHz
   

Main Chassis

Dimension (mm) 290*210*60
Weight 2.6 kg
Working Temperature -30~70℃
Humidity 5%~95% RH
Consumption 10W
Power 90~280VAC (50~60Hz)
Enclosure Rating IP42 (for CE Marking)
PC Connection high-speed standard Ethernet interface
Anti-vibration Performance 10-60 Hz @ 0.15 mm peak, 60-150 Hz @
  2 gn, conform to IEC-68-2-6; 5~55Hz~5Hz @ 0.19 mm peak, conform to GB/T6587-2012 standard II
Anti-impact Performance Half sine 10 gn for 16 ms, conform to IEC-60068-2-27; Half sine 30 gn for 11 ms, conform to GB/T 6587-2012 standard II
EMC Standards EN 55022: 2010, EN55024:2010, EN 60950-1: 2006+A12:2011
  +A1:2009+A2:2009, EN 61000-3-3:2008
Safety EN 61010-13rd
Compliance CE Marking

Software

Trigger

Trigger Channel Any active channel, specified channel ornone
Trigger Slope Rising, Falling and Bi-slope
Trigger Level Specified G level
Delay -100%-100%

Ideal Waveform

Waveform Half-sine, Initial/Final peak sawtooth, Triangular,Rectangular, Trapezoid, Haversine
Standard ISO, MIL-STD-810G, IEC, User defined
Tolerance According to each standard

SRS Analysis

Analysis Target Ideal Waveform or set SRS manually
SRS type Primary, Residual, and Composite
Resolution 1-1/48 octave analysis
Damping Ratio 0.1%-99%
Q factor 0.5-500

Filtering

Low-pass and high-pass filters, specified cutoff frequency and filter ratio. Filters are independent for each channel.

Shock Response Analysis

Specified arbitrary frequency and damping ratio, generate its impact response signal.
SR Visualizer 2D pulse animation from high to low frequency
  3D pulse animation from high to low frequency
  Replay 3D pulse animation from high to low frequency

Force/Deflection Analysis

Calculate and display Force/Deflection curve, Ideal Energy, Input Energy, Absorbed Energy, Lost Energy and Efficiency.

Rotational Shock Analysis

Set the turning radius, calculate angular acceleration time-domain signal.

FFT Analysis

Calculate FFT signal of each channel.
Close
Account Group
Username:
Password: